ENSONIQ ASR-10 Manuel d'instructions Page 188

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 390
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 187
Section 10 — Wave Data Parameters ASR-10 Musician’s Manual
8 Command/Wave Page
CMD
REVERSE CROSS FADE
WAVE
Press Command / Wave / 6
The REVERSE CROSS FADE loop command helps eliminate tonal bumps, and smoothes out the
tonal content of the loop. REVERSE CROSS FADE works well with multiple source sounds such
as string sections, brass ensembles, and choirs. The default and manual values are the same as in
the CROSS FADE LOOP command.
LE
WE
LE
LS
LS
Loop length
INTERMEDIATE RESULT:
0% 100%
Copy &
reverse
Fade out loop, ...
copy and reverse loop data, ...
and add reversed copy
REVERSE CROSS FADE LOOP
WS
(first step before regular Cross Fade Loop)
(then a Cross Fade Loop is performed using the intermediate result)
WS WE
Select REVERSE CROSS FADE. Press Enter•Yes.
The screen will ask, USE DEFAULT VALUES? Press Enter•Yes.
Pressing Cancel•No in response to USE DEFAULT VALUES, prompts the ASR-10 to display
the manual values for this command. Use the Left/Right Arrow buttons to scroll to select
SCALE DEPTH=## DB and FADE ZONE (PERCENT)=##. Press Enter•Yes.
The display reads KEEP=OLD NEW. Press Enter•Yes to complete the command (or
Cancel•No to keep the original).
Note: When STEREO LAYER LINK= ON, this command will be simultaneously performed on the
corresponding WaveSample in the companion layer.
CMD
ENSEMBLE CROSS FADE
WAVE
Press Command / Wave / 7
ENSEMBLE CROSS FADE is essentially a cross fade loop with the FADE ZONE set to l00%. If
you use the default values, the ASR-10 may tell you DEFAULTS CANNOT BE SET. Then it will
advise, INCREMENT LOOP START or, DECREMENT LOOP END (Edit/Wave page). This is
because the data preceding the loop is shorter than the loop itself. For ENSEMBLE CROSS FADE
to work, the fade zone must be l00% of the loop length. You can either make sample start smaller
so that you add more data preceding the loop, or move the loop around using loop position on
the Edit/Wave page. The only manual value here is SCALE DEPTH which is the same as in the
CROSS FADE LOOP command. The fade zone is not a parameter, because it is always assumed
to be l00% of the loop length.
Select ENSEMBLE CROSS FADE. Press Enter•Yes.
The display reads USE DEFAULT VALUES? Press Enter•Yes.
Pressing Cancel•No in response to USE DEFAULT VALUES, prompts the ASR-10 to display
the manual values for this command. Use the Left/Right Arrow buttons to scroll to select
SCALE DEPTH=## DB. Press Enter•Yes.
Vue de la page 187
1 2 ... 183 184 185 186 187 188 189 190 191 192 193 ... 389 390

Commentaires sur ces manuels

Pas de commentaire