ENSONIQ ASR-10 Manuel d'instructions Page 315

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 390
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 314
Section 14 — Storage
Loading Instruments and Banks 5
Loading and Saving ASR-10 Instruments
Loading an Instrument
You can load up to eight different instruments into the ASR-10 at once (within the limits of
memory). First, insert a disk containing one or more instrument files into the disk drive.
• Press Load. The LOAD indicator flashes.
• Press Instrument. The display might look like this:
LOAD INST STOP
When the LOAD indicator is flashing, the ASR-10 is showing you disk files (think of it as a
question mark - the ASR-10 is saying “Load the file showing on the display?”). Pressing the
Up/Down Arrow buttons takes you through the files on the disk. If there are none, the display
will read “NO INST OR BANK FILES.”
Whenever a disk file is displayed as above, you can press the Left or Right Arrow button to see
the size of that file in Blocks (a Block is 256 samples; 4 Blocks=1K samples). Press the Left or
Right Arrow button again to return to the file name.
Use the Data Entry Slider or the Up/Down Arrow buttons to view the various instrument files
on the disk. Each file has its own File Number. When an instrument file is showing, the INST
indicator is lit. The BANK indicator will light when a bank file is showing.
Find the instrument you want to load, and press Enter•Yes. The display will say PICK
INSTRUMENT BUTTON. The ASR-10 is asking in which instrument location you want to
load the sound into.
Press any of the eight Instrument•Sequence Track buttons. The ASR-10 will begin
immediately loading the instrument into the selected location. The display reads LOADING
FILE… and the left red LED flashes while the instrument is being loaded.
LOAD INST STOP
Once the instrument has been loaded, the display briefly shows “FILE LOADED.” The left red
LED above the Instrument•Sequence Track button stops flashing and remains solidly lit,
indicating that there is now an instrument loaded in that location which can be selected by
pressing that button.
If you tell the ASR-10 to load an instrument into a location that already has an instrument loaded
(left red LED lit), the new instrument will be loaded into that location and the one that was there
will be automatically deleted.